Nov 24, 2026

Technical Key Points Of RTCA DO-160 Icing Test

Leave a message

news-650-433
Technical Key Points of RTCA DO-160 Icing Test

The icing environment simulation experiment of GRGTEST is conducted to determine the performance characteristics of equipment that must operate when exposed to icing environments, which occur during rapid changes in temperature, altitude, and humidity.

Test Objective

 

To determine the performance characteristics of equipment that must remain operational when exposed to icing conditions. Such conditions typically arise from rapid changes in temperature, altitude, and humidity. Three effects are evaluated:

  • Adhesion of external ice or frost to the equipment;
  • Ice formed by the freezing of condensed water or the re-freezing of melted ice;
  • Ice accretion resulting from direct exposure to water.

 

Categories and Applicability (selected by installation location and expected icing conditions)

 

  • Category A: Equipment mounted on the aircraft exterior or in non-temperature-controlled areas. After cold soak at extreme low temperature, the equipment encounters moist air above freezing, causing condensation that subsequently freezes or forms frost on the surface.
  • Category B: Equipment with moving parts. Ice may obstruct or restrict movement, or the force of ice expansion may damage structural or functional components. Ice forms inside or on the equipment through condensation, freezing, melting, and/or re-freezing, and may gradually accumulate as water or ice within a non-sealed enclosure.
  • Category C: Equipment mounted on the exterior or in non-temperature-controlled areas where free water may accumulate and subsequently freeze on cold surfaces. This test verifies the effect of typical ice thickness on performance, or determines the maximum allowable ice thickness before de-icing becomes necessary (thickness, distribution, and progressive accretion shall be specified in the relevant equipment performance standard).

 

news-935-329

 

Test Procedure Essentials

 

  • Category A: With the equipment inoperative, stabilize it at the ground low-temperature endurance temperature, then expose it to 30 °C with RH ≥ 95%. Hold until the surface temperature reaches 5 °C, then return rapidly to the low-temperature condition. Repeat for a total of 3 cycles. At the end of the final cycle, stabilize at −10 °C ± 5 °C, energize the equipment, and verify compliance with the performance standard.
  • Category B: With the equipment inoperative, stabilize at −20 °C; reduce chamber pressure and hold for at least 10 min. Raise the chamber temperature at ≤ 3 °C/min while maintaining RH ≥ 95% (chamber temperature ≤ 30 °C) until all frost and ice melt or the surface reaches 0–5 °C. Restore ambient pressure uniformly over 15–30 min. Repeat for a total of 25 cycles (or as otherwise specified in the equipment specification, whichever is less). Verify performance at −20 °C during the final cycle.
  • Category C: With the equipment inoperative, stabilize it at a temperature at which transparent, hard ice forms (approximately −1 °C to −10 °C). Spray a fine mist of water near the freezing point until the required ice thickness builds up. Stop spraying, energize the equipment, stabilize at −20 °C, and verify performance. White ice or ice containing air pockets is not acceptable.

 

GRGTEST Icing Test Capabilities and Service Advantages

 

  • Standardized workflow: Conduct a background investigation of the sample first-fully understanding its manufacturing process and installation location-to select appropriate test conditions; then confirm that the sample dimensions meet the requirements.
  • Standards and test items: In accordance with RTCA/DO-160 (E/F/G), covering Category A (3 cycles), Category B (25 cycles), and Category C (surface ice thickness reaching the specified value).
  • Customized services: Professional, customized solutions are available for special requirements during testing, such as the need for air supply, oil supply, or electrical power.
  • Qualifications and facilities: Accredited by CNAS and qualified by COMAC (Commercial Aircraft Corporation of China); operates 18 reliability and environmental laboratories nationwide, with capabilities spanning climatic, combined-environment, and mechanical-environment testing, as well as reliability and failure analysis.
  • Program experience: Has undertaken tests for key aircraft programs including C919, AG600, and ARJ21; equipped with multiple types of icing test facilities, with a typical test turnaround of approximately 2 weeks.
CMA1
 
CBAS
 
cwr-tyest
 
ISO

 

Engineering Implementation Notes

 

Before testing, remove non-typical contaminants such as oil, grease, and dust, and install the specimen in a manner representative of normal aircraft installation. Tests are performed in accordance with Section 24 of RTCA/DO-160 E/F/G.

 

Send Inquiry