A Guide To The New Absorbing Clamp Method For Screening Or Coupling Attenuation

Leave a message

I. Standard Overview


On March 31, 2026, the Standardization Administration of China approved and issued GB/T 31723.405-2026 Metallic Communication Cable Test Methods-Part 4-5: Electromagnetic Compatibility-Screening or Coupling Attenuation-Absorbing Clamp Method, under the jurisdiction of SAC/TC190. The standard fully replaces GB/T 31723.405-2015 and took effect on October 1, 2026.

 

news-1-1

 

II. Core Content

 

Specifies the absorbing clamp method for determining coupling or screening attenuation of metallic communication cables, covering 30 MHz–1000 MHz, extendable to 2400 MHz depending on absorbing clamp performance.

Can serve as an alternative to the triaxial method specified in IEC 62153-4-4 or IEC 62153-4-9.

The standard does not specify the external circuit for the absorbing clamp method; results may vary between test positions and laboratories, with measurement deviation up to over ±6 dB. Attention is needed in test comparison and result evaluation.

The new edition updates and improves test operations, apparatus requirements and result interpretation, providing a unified test basis for EMC evaluation of screening performance.

 

III. Scope and Limitations

 

Applicable to metallic communication cables with metallic shielding layers, using the absorbing clamp method to measure screening attenuation and coupling attenuation.

Not directly applicable to transfer impedance testing of connectors and cable assemblies (corresponding to GB/T 31723.407); cannot replace the line injection method (GB/T 31723.406) for obtaining surface transfer impedance parameters.

Principle: an external electromagnetic field induces common-mode current on the outer surface of the cable shield; the absorbing clamp captures the common-mode RF current on the shield; attenuation is calculated from the ratio of excitation power to picked-up power.

 

IV. GRGTEST Service Capabilities


GRGTEST has established a complete technical capability system supporting implementation of the new standard. It is equipped with signal generators, spectrum analyzers, measuring receivers and a low-background-noise shielded room, and has mastered the full-process absorbing clamp method for coupling/screening attenuation testing. GRGTEST can conduct tests in accordance with the new standard and issue professional test reports.